Description
CMS6500 6-Parameters ICU Patient Monitor, ECG + NIPB + SPO2 + PR + RESP + TEMP, Touch Screen Medical Monitoring Device
CMS6500 is a portable monitor with touch screen. To ensure monitoring quality and reduce operation risk, it adopts full-isolation (floating), ECG defibrillation-proof protection, ECG anti-high frequency surgical unit and NIBP dual-overpressure protection.
Features
- Display mode: 7\’\’ color TFT LCD with high-resolution.
- Simple and shortcut for operating with touch screen.
- Be applicable for adult, pediatric and neonatal for all-round monitoring.
- Waveform and data can be set optionally.
- Storage of 72-hour trend data, and review of 40-second holographic waveform.
- Full-lead ECG display.
- Anti-high frequency surgical unit, defibrillation-proof(requirement for special leads).
- Adopt digital SpO2 technology, which has strong anti-interference and anti-weak filling capability.
- Function of NIBP review, storage for up to 400 NIBP data.
- Network: connecting with central station, other Bed observation and software updating.
- Network connection mode: wireless and wired.
- Built-in rechargeable battery for uninterrupted monitoring.
- Standard parameters of ECG, RESP, NIBP, SpO2, TEMP and PR.
Performance
- ECG
- Lead Mode 3-lead and 5-lead are optional
- Lead Selection I, II, III, avR, avL, avF, V
- Wave 1 channel
- Gain ×0.25, ×0.5, ×1, ×2.
- HR Measuring and alarm Range
- Range 15 ~ 300 bpm
- Accuracy ±1% or ±1bpm, which is greater.
- Alarm Accuracy ±2bpm
- Resolution 1 bpm
- ST Segment Monitoring
- Measuring and Alarm Range -0.6 mV~ + 0.8 mV
- ARR Detecting Type ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC
- Alarm Available
- Review Available
- Scan Speed for ECG Waveform 12.5mm/s, 25mm/s, 50mm/s
- NIBP Monitoring
- Measurement method: Oscillometry
- Measurement mode: manual/auto/continuous.
- Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90 Min.
- Measuring Period in Continuous Mode 5 Min
- Measuring and Alarm Range 10~270mmHg
- Resolution 1 mmHg
- Accuracy ±10% or ±8mmHg, which is greate
- Over-pressure Protection
- Adult Mode 315±10 mmHg
- Pediatric Mode 265±10 mmHg
- Neonatal Mode 155±10 mmHg
- SpO2 Monitoring
- Measuring and Alarm Range 0 ~ 100 %
- Resolution: 1%
- Accuracy: 70% ~ 100% ±2, 0% ~ 69% unspecified
- Pulse Rate:
- Measuring and Alarm Range 0~250bpm
- Resolution 1bpm
- Accuracy: 2bpm or 2%, whichever is greater.
- Alarm Accuracy ±2bpm
- Respiration(RESP)
- Method R-F(RA-LL) Impedance
- Measuring and Alarm Range for Resp. Rate
Adult 0~120rpm
Pediatric and Neonatal 0~150rpm
Resolution 1 rpm
- TEMP
- Channel 1 channel
- Measuring and Alarm Range 0 ~ 50°C
- Resolution 0.1°C
- Accuracy ±0.1°C
Accessories
- Main Unit
- Integration extension cable(5-pin)
- Adult fingertip SpO2 probe(DB9)
- Adult NIBP cuff
- Extending tube for NIBP
- ECG lead
- ECG electrode
- Temperature probe
- Power cord
- Power adapter
- User Manual
Dimensions and Weight
- Dimension: 190(L)*160(W)*240(H)mm
- Weight: 2.1kg
Certification :
CE, CCC, FDA