CONTEC PM50 Portable Blood Pressure NIBP/Spo2 Patient Monitor+Cuff+Probe NEW

  Ask a Question
Compare

$318.40

In stock

Compare

Description

Portable Vital Sign Patient Monitor, NIBP+SPO2+PR, PC Software, USA
Description
PM50 is a multi functional patient monitor, it can monitor SPO2 and NIBP for a long time, and applies to the hospital wards or family daily health care.

Major Features
1.Compact and portable, easy to use
2.With Integrative SpO2 Probe
3.Double working modes,monitoring function and 24 hours ambulatory NIBP measure function can be flexibly set
4.NIBP and SpO2 can be monitored for a long time
5.NIBP and SpO2 data record for large capacity
6.With friendly user interface, the user can see list menu and review measure results
7.The device can display low power information, alarm information, error information and time information richly
8.Parameter alarm function is optional
9.Patient information can be flexibly set
10.Case management function.PC software can achieve data review, analysis measure results, seeing trend, printing reports and other functions

Main performance
1.NIBP Measure Method: Oscillometry
Measure Mode: The upper arm measure
Measure range: ADULT: SYS: 40mmHg~270mmHg MAP:20mmHg~235mmHg DIA: 10mmHg~215mmHg PEDIATRIC: SYS: 40mmHg~200mmHg MAP: 20mmHg~165mmHg DIA: 10mmHg~150mmHg NEONATAL: SYS: 40mmHg~135mmHg MAP: 20mmHg~110mmHg DIA: 10mmHg~100mmHg

Automatic measure Interval: 5,10,15,20,30,45,60,90,120 minutes
Resolution: 1mmHg Accuracy: ±3mmHg
Increasing pressure mode: force pump increases pressure automatically
Reducing pressure mode: self-motion ladder reducing pressure mode
Alarm parameter: SYS / MAP / DIA 2.SPO2
Measure range: 0%~100% (Resolution:1%)
Accuracy: 70-100%, ±2%, below 70%
Error in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Pulse Rate Measuring range:0bpm~250bpm Resolution:1bpm Accuracy: ±2 bpm or ±2% (select larger)
Display: 2.4″ TFT colour LCD
Power: DC 3V(Two “AA”,1.5V Alkali Battery)
Product safety type:Type BF applied part (Internally powered,defibrillation-proof)
Accessories Cuff for adult, cuff for adult large, and cuff for adult leg(3 pcs in all) Integrative SpO2 Probe USB data line Disk (PC software) Pack User manual

Physical Identity
Dimension: 128mm x 69mm x 36 mm (No including Packing)
Weight: <350g (Including Batteries)

Qualification: Passed CE FDA
Software Function
1.Up to 1000 patient cases can be edited and supervised.
2.The time segment of dealing with the patient’s NIBP data is 48 hours.
3.Connect the device by USB interface.
4.Can upload patient information data collection project and download collection data.
5.Can display scoop-shape trend graph,filling-type trend graph, histogram, pie chart, correlation line graph.
6.Can edit every piece of data, and add annotation to it.
7.Can edit basic information,doctor’s advice information, NIBP and SpO2 status instruction, current medicine-taken information, etc. Support print preview, print the report.

ECG / ECG holter EEG / EEG Holter B-ultrasound Scanner

Patient Monitor Fetal doppler Fetal Monitor

Spo2 Monitor Stethoscope Medical Image

 

Reviews (0)

0.0
0
0
0
0
0

Only logged in customers who have purchased this product may leave a review.

There are no reviews yet.

No more offers for this product!

General Inquiries

There are no inquiries yet.

0